2000 KW DDC-MTU Generating Units

FOR SALE

(5) THREE UNUSED MODINE

ENGINE DRIVEN RADIATORS

OFF 2000 KW SPECTRUM / KOHLER

GENERATING UNITS

2008 & 2007 IMMEDIATE SHIPMENT

Qty. 3 – Unused Modine engine fan driven radiators originally installed on 2000KW Spectrum/Kohler/DDC-MTU generating units. Kohler P/N A-354957. Modine P/N 1A18162 Includes belt driven fan asm. Built in 2000.

Application Data for cooling system:                               60 hz                                            50 hz

Ambient temperature deg C/(deg F)                                 40(105)                                  50(122)

Engine jacket water capacity, L(gal)                                  151(40)                                  151(40)

Radiator system capacity, incl. engine, L(gal.)                565(150)                               565(150)

Engine jacket water flow, Lpm(gpm)                                1703(450)                              1420(375)

Charge cooler water flow. Lpm(gpm)                               757(200)                                606(160)

Heat rejected to cooling water at rated

KW, dry exhaust KW (Btu/min)                                           799(45434)                           769(43708)

Fan diameter, including blades, mm(in)                         1880(74)                                1880(74)

Fan kWm (HP)                                                                      72(97)                                     86(115)

Max. restriction of cooling air, intake and

discharge side of rad., kPa(in. H2O)                                 0.125(0.5)                             0.125(0.5)

 

Approximate dimensions:                           Width:  7’-10” x Depth: 3’-6” x Height: 9’-9”                    

 

Approximate shipping weight:                                7,000 lbs

Details / Specifications
Name
Quantity1
ManufacturerSpectrum