75,000 PPH Optimus 750 PSI Saturated
Request a QuoteKey Features
Trailer Mounted for Easy Transportation
- Low NOx Burner
- 750 PSIG Design
Have a Question?
Whatever you need, Wabash Power has the inventory, the expertise and the commitment to deliver the highest quality equipment faster than the rest. Contact us or give us a call today!
Details / Specifications
description
75,000 lb/hr Optimus Saturated Steam
manufacturer
Optimus/Chaunte Manufacturing
year built
2008 and Newer
burner manufacturer
Todd / Coen
Steam Capacity (PPH)
75000
code design
Built in accordance with ASME Code and bearing National Board stampings. Includes burner with NEMA IV construction for weather-tight outdoor installation. Includes All Canadian CRN.
transformer
480V/120V control circuit transformer
Design Pressure (PSIG)
750
dimensions
95' -0 L x 11' -6\ W x 14' -4"H"""
drum type
O Type Boiler
fan type
Forced draft fan with 150 HP TEFC electric motor drive 3/60/480V with starter
flame monitoring system
Fireye E 110 microprocessor based flame management system
freight method
Trailer
fuel
Natural Gas / Oil
NOx With FGR
30 PPM
operating pressures
350-675
starting system
TEFC motor with starter
steam type
Saturated
steam temp
Up to 510° At Saturation
sortorder
0